SLQK/SLP/SLU series DIN railscrewless quick terminals
Place of Origin
Zhejiang,China
Model Number
SLP, SLP-QU, SLP-QU-With baffle, SLP-With baffle, SLQK, SLU, SLU-With baffle
Color
black, Blue, green, orange, Red, yellow |
Rated Current
24A, 32A
Rated Voltage
250V, 400V
Mounting
Din rail
Material of Shell
Nylon PA66
Metal Material
Copper conductive strip
Operating temperature
-20℃-105℃
Wire Range
0.2-4.0mm² |
SKQK series single-input multi-output splitter
SLU
SLU
Model
Special color
Rated Current
Voltage
Length/Width/High
Stripping length
Wiring range
Operating Temperature
Casing material
SLU
Grey
24A
250V
35.6mmx27mmx5mm11mm
11mm
0.2-4mm
-20°C-105°C
PA66
SLP
SLP
Model
Special color
Rated Current
Voltage
Length/Width/High
Stripping length
Wiring range
Center-type jumper
Casing material
SLP
Gray
24A
250V
34.6mmx27mmx6mm
11mm
0.2-4mm
-20°C-105°C
PA66
SLP-QU
SLP-QU
Model
Special color
Rated Current
Voltage
Length/Width/High
Stripping length
Wiring range
Center-type jumper
Casing material
SLP-QU
Gray
24A
600V
67.4mmx27.3mmx5.5mm
11mm
0.2-4mm
-20°C-105°C
PA66
SLQK
Model
Special color
Rated Current
Voltage
Length/Width/High
Stripping length
Wiring range
Center-type jumper
Casing material
SLQK
Gray
32A
600V
45mmx30mmx6mm
11mm
D-MBK3/5
FB1 10-5
PA66
Why Choose Arbolsol Shengling SLQK/SLP/SLU Series Push-in Terminal Blocks?
For the SLQK / SLP / SLU series DIN rail push-in terminal blocks, thedesign focuses on fast wiring and secure connection. The push-inmechanism allows quick, tool-free installation, ideal for control cabinetsand high-density wiring applications.
Key advantages:
· Fast wiring: Push-in operation, no tools required· High conductivity: Thick copper conductor for stable performance· Secure clamping: Stainless steel spring ensures strong, vibration-
resistant contact
· Safe housing: Flame-retardant nylon for enhanced safety·Flexible expansion: Modular design for multi-position combinationsEasy mounting: Standard DIN rail installation, compact and space-
saving.
Product Details
This Din Rail-mounted screwless quick connector supports highly customizable configurations to meet diverse industrial wiring needs.
Its core strength lies in ultimate flexibility and convenience: the advanced detachable modular design grants users unprecedented freedom. You can easily assemble or disassemble modules based on specific application scenarios, customizing configurations to achieve truly flexible wiring.
Home Renovation Wire Selection Guide: BV vs. BVR Specifications & Applications
Choosing the correct wire gauge is crucial for electrical safety and system stability in home improvement. Below is a reference guide for selecting wire specifications based on common residential scenarios to help you plan your circuit layout scientifically.
BV Wire (Solid Core): Ideal for Fixed Wiring
1.5mm²: Dedicated to general lighting circuits, handling standard lamp loads.
2.5mm²: Suitable for standard power outlets and regular air conditioning lines, balancing safety and cost.
4mm²: Specifically for high-power appliances like electric water heaters and cabinet AC units, ensuring stable power under high loads.
BVR Wire (Stranded Core): Ideal for Flexible Bending
1.5mm²: Used for socket connections, offering ease of wiring in confined spaces.
2.5mm²: Applicable for regular AC lines, offering superior flexibility for easier installation.
4mm²: Designed for high-power equipment such as water heaters or standing AC units; the stranded structure offers better heat dissipation and reliable connections.
Feature Overview: Efficient Power Distribution & Signal Transmission Solutions
1-in-Many-out Distribution: Supports single-input multi-output mode, perfectly realizing centralized power distribution or signal splitting to simplify wiring complexity.
Rapid Tool-free Wiring: Features advanced push-in connection technology, enabling quick wiring without screwdrivers and significantly boosting installation efficiency.
Flexible Modular Expansion: Built with a highly scalable modular architecture, supporting free combination and splicing to easily adapt to diverse application scenarios.
Easy Maintenance & Visibility: Equipped with clear marking areas for easy line identification and management, making routine maintenance and troubleshooting more efficient.
Secure & Robust Design: Compact and solid structure ensures long-term stable and reliable contact points, providing excellent safety assurance for electrical systems.
Achieve Efficient 1-in-Many-out Wiring Solutions
This DIN rail terminal block is engineered to optimize circuit distribution. It supports flexible expansion via jumper bars, easily enabling rapid “1-in-many-out” line allocation. Users can freely combine jumper bars of varying positions based on actual power consumption and current requirements to achieve precise power or signal splitting.
Featuring a plug-and-play bridge design, this product allows for easy installation without complex tools. Simply insert the jumper bar into the slots of adjacent terminals to instantly complete the electrical parallel connection. This significantly reduces wiring time and improves the neatness of control panel layout.
SLQK / SLP / SLU Terminal Blocks wiring method
Want to see more terminal wiring videos?
Then follow me!
Real photos of rail-mounted screwless quick terminals
Common problems with SLQK/SLP/SLU series rail-mounted screwless quick terminals
What are the differences between SLQK/SLP/SLU series screwless quick-connect terminals and traditional terminalblocks?
This type of terminal block is commonly known as a spring terminal block, lever -type quick-connect terminal block or rallterminal block. Is keyselling points are screwless operation, quick wiring and reusable assembly and disassembly, making it suitable for wiring scenarios in distributioncabinets, control cabinets, lighting, and equipment.
What types of wires can be connected to screwless quick-connect terminals? Can they accept single-strand wires orstranded wires?
Common models can be used with solid wires and multi-strand wires with cold -pressed terminals, and some products also support directconnection to mult -strand wires; however, whether drect connection is possible or whether crimping is required depends on the productspecification.
What is the maximum wire thickness that the SLQK/SLP/SLU series DIN rail screwless quick-connect terminals canconnect to?
The SLQK/SLP/SLU series DIN rail screwless quick-connect terminal block has a wire cross-section of 0.2-4mm.
Common problems with UK series universal screw terminal blocks
Are UK terminal blocks easy to operate?
This type of terminal block is commonly known as a spring terminal block lever-type quick-connect terminal block, or ral terminal block. Its keyselling points are screwles operation, quick wiring and reusable assembly and disassembly, making it suitable for wiring scenarios in distributioncabinets, control cabinets, lighting, and equipment.
Will the UK terminal blocks overheat and burn out?
Under normal use, i wil not cause overheating. but f there is poor contac,. oose screws overoad of the selected wire, or mismatch between wrediameter and terminal specifications, i may cause overheating, and in severe cases, it may burn black or even burn out.
What scenarios are UK terminal blocks suitable for?
Commonly found in:
Control cabinets.
Distribution boxes.
Automation equipment.
Industrial control systems.
Electrical installation scenarios requiring neat wiring.
What should I ask most when buying UK terminal blocks for the first time?
The most crucial factors are:
What wire diameter is required?
Rated current.
Rated voltage.
Applicable temperature range.
Does the flexible wire need to be terminated?
Is it suitable for DIN rail mounting?
Common problems with UK series universal screw terminal blocks
Are UK terminal blocks easy to operate?
This type of terminal block is commonly known as a spring terminal block lever-type quick-connect terminal block, or ral terminal block. Its keyselling points are screwles operation, quick wiring and reusable assembly and disassembly, making it suitable for wiring scenarios in distributioncabinets, control cabinets, lighting, and equipment.
Will the UK terminal blocks overheat and burn out?
Under normal use, i wil not cause overheating. but f there is poor contac,. oose screws overoad of the selected wire, or mismatch between wrediameter and terminal specifications, i may cause overheating, and in severe cases, it may burn black or even burn out.
What scenarios are UK terminal blocks suitable for?
Commonly found in:
Control cabinets.
Distribution boxes.
Automation equipment.
Industrial control systems.
Electrical installation scenarios requiring neat wiring.
What should I ask most when buying UK terminal blocks for the first time?
The most crucial factors are:
What wire diameter is required?
Rated current.
Rated voltage.
Applicable temperature range.
Does the flexible wire need to be terminated?
Is it suitable for DIN rail mounting?